Electric Linear Slides EAS Series
EAS4LX-D025-ARAS
Actuator/Control Circuit
Product Classification | Product Name | List Price | Shipping Date |
---|---|---|---|
Actuator / Control Circuit | EAS4LX-D025-ARAS | - | Product to be Discontinued (31.1.2025 order deadline) |
- *Please contact Oriental Motor about purchasing this product.
- *The order deadline for products to be discontinued is 31.3.2025.
Included
- Actuator, Control Circuit, I/O Signal Connector, Connector for Regeneration Resistor Input/Main Power Input Terminals, 24 VDC Power Supply Input/Regeneration Resistor Thermal Input/Electromagnetic Brake Output Terminal, Connector Wiring Lever
Specifications
Data Download
Other Specifications
Circuit Specifications
Built-In Controller Type |
Pulse Input Type | ||
---|---|---|---|
Maximum Input Pulse Frequency | − | Line Driver Output by Host Controller: 500 kHz (at 50 % duty) Open-Collector Output by Host Controller: 250 kHz (at 50 % duty)*1 Negative logic pulse input (initial value) |
|
Number of Positioning Data Sets | 64 Points | − | |
Positioning Operation | Independent | ◯ | − |
Linked | ◯ | − | |
Linked 2 | ◯ | − | |
Sequential | ◯ | − | |
Direct | ◯ | − | |
Pushing | ◯ | ◯*2 | |
Continuous Operation | ◯ | − | |
JOG Operation | ◯ | − | |
Return-To-Home Operation | ◯ | − | |
Test Operation | ◯ | ◯*2 | |
Absolute-position backup system | ◯ | − | |
Control Module OPX-2A | ◯ | ◯ | |
Support Software MEXE02 | ◯ | ◯ |
- *1
- The value when the general-purpose cable (CC36D1E) (sold separately) is used.
- *2
- Setting by extended function (MEXE02)
General Specifications
AC Input
Motor Section (AR Series) | Driver | |||
---|---|---|---|---|
Built-In Controller Type | Pulse input type | |||
Thermal Class | 130 (B) | − | ||
Insulation Resistance |
100 MΩ or more when 500 VDC megger is applied between the following places.
|
100 MΩ or more when 500 VDC megger is applied between the following places.
|
||
Dielectric Strength |
Sufficient to withstand the following for 1 minute:
|
Sufficient to withstand the following for 1 minute: | ||
|
|
|||
Operating Environment (When operating) |
Ambient Temperature | 0~+50 °C (Non-freezing)*2 | 0~+55 °C (Non-freezing)*3 | 0~+50 °C (Non-freezing)*3 |
Ambient Humidity | 85 % max. (Non-condensing) | |||
Atmosphere | No corrosive gases or dust. No exposure to water, oil or other liquids. | |||
Degree of Protection | IP65 (Motor section only. Except for the connector) | IP10 | IP20 |
- *1
- (Only for types with electromagnetic brake)
- *2
- The temperature range of the electric linear slide is 0~+40 °C.
- *3
- When installing a heat sink equivalent to an aluminum plate min. 200×200 mm, thickness 2 mm
Note
- Do not perform the insulation resistance test or the dielectric strength test while the electric linear slides (motors) and drivers are connected.
DC Input
Motor Section (AR Series) | Driver | |||
---|---|---|---|---|
Built-In Controller Type | Pulse input type | |||
Thermal Class | 130 (B) [Certified at 105 (A) when UL/CSA Standards were obtained] |
− | ||
Insulation Resistance |
100 MΩ or more when 500 VDC megger is applied between the following places.
|
100 MΩ or more when 500 VDC megger is applied between the following places.
|
- | |
Dielectric Strength |
Sufficient to withstand the following for 1 minute:
|
Sufficient to withstand the following for 1 minute:
|
- | |
Operating Environment (When operating) |
Ambient Temperature | 0~+50 °C (Non-freezing)*2 | 0~+50 °C (Non-freezing) | |
Ambient Humidity | 85 % max. (Non-condensing) | |||
Atmosphere | No corrosive gases or dust. No exposure to water, oil or other liquids. | |||
Degree of Protection | IP20 (motor section only) | IP10 | IP20 |
- *1
- (Only for types with electromagnetic brake)
- *2
- The temperature range of the electric linear slide is 0~+40 °C.
Note
- Do not perform the insulation resistance test or the dielectric strength test while the electric linear slides (motors) and drivers are connected.
Travel Direction
At the time of shipment, the travel direction of the table is set as follows.
Calculating Load Moment
When a load is transported with an electric linear slide or electric cylinder (a unit equipped with shaft guide covers only), the load moment acts on the linear guide/shaft guide if the position of the load's center of gravity is offset from the center of the table/center of the shaft guide. The direction of action applies to the directions for pitching (MP), yawing (MY), and rolling (MR), depending on the position of the offset.
Even though the selected electric actuators satisfy the load mass and positioning time requirements, when the center of gravity of the load is overhung from the table's center/shaft guide’s center, the run life may decrease as a result of the load moment. Load moment calculations must be completed and whether the conditions are within specifications values must be checked. The moment applied under static conditions is the static permissible moment. The moment applied under movement is the dynamic permissible moment, and both must be checked.
Calculate the load moment of the electric linear slides and electric cylinders (units equipped with shaft guide covers only) based on loads that are applied. Check that the static permissible moment and dynamic permissible moment are within limits and check that strength is sufficient.
- *For more information on calculating static permissible moment and dynamic permissible moments, click here.
Load Moment Formula
When there are several overhung loads, etc., it is determined by the sum of moments from all loads.
For Multiple Loads (n)
Standards
Regulations and Standards Materials
Documents about compliance with regulations and standards can be downloaded from the "Data Download" tab on the product details page.
(The types of files available for download vary by product.)
Explanations of the Global Laws, Regulations and Standards can be found here.
Information about our compliance with regulations and standards for each of our product series can be found here.
Hazardous Substances
The product does not contain any substances (10 substances) exceeding the regulation values of the RoHS Directive (2011/65/EU, 2015/863/EU).
System Configuration
Cables and Accessories