Q.I have 4 drivers connected to a NETC02-CC. There is no problem with address number 0, but address number 1~3 cannot be controlled by remote I/O and set the operation data. What are the possible causes?
Please check the setting of N-AXIS (RS-485 communication connection number setting switch) for NETC02-CC. If it is set to the initial value of "1," only address number 0 can be controlled and configured with remote I/O via CC-Link.
Change the setting according to the number of connections. (For 4 units, set to "4.")

The N-AXIS setting status can be checked by the number of LED lights in the RS-485 LINK STATUS area on the front panel of the NETC02-CC. Please use these LEDs to confirm N-AXIS changes have been reflected.
-
[When N-AXIS is Set to "1"]
-
[When N-AXIS is Set to "4"]
Product Category: Controller and network compatible products
Model and Series: NETC02-CC
Description: Usage and setting methods, abnormalities and problems
FAQ No.: 460
Related FAQs
-
- Q458.
- I am using the NETC02-CC with the command fixation method, but the position data setting is not reflected. What are the possible causes? | FAQ Search
-
- Q459.
- I am using the NETC02-CC with the command selection method, but changes to the operation data and parameters are not reflected. What are the possible causes? | FAQ Search
After opening the email, we will check the contents and contact you. Please note that depending on your inquiry, we may call you back.