The specialist of small precision motors - ORIENTAL MOTOR (INDIA) > Q&A > Standard AC Motor Question 18:Using 6W torque motor (TM series) and i encounter heat generation issue. When I touch both the motor surface, it is very hot. The application is for winding up the wire but after sometimes the motor stops running
Standard AC Motor: Using 6W torque motor (TM series) and i encounter heat generation issue. When I touch both the motor surface, it is very hot. The application is for winding up the wire but after sometimes the motor stops running. What could be the issue?
Question 18: Using 6W torque motor (TM series) and i encounter heat generation issue. When I touch both the motor surface, it is very hot. The application is for winding up the wire but after sometimes the motor stops running. What could be the issue?

Answer:
For torque motor, there is a 5 minutes rating for the motor. Whereby, the operation duty cycle cannot be at 100%. If you require a torque motor to run continuously, you will need to use a bigger size torque motor i.e. 20W, and run it at half it's rated voltage, this would allow the heat to saturate at a certain point.