Linear Slide, Control Circuit, Cable for Motor(3m), Cable for Electromagnetic Brake(3m), Connector for I/O Signal, Sensor Signal Connector, Connector for Regeneration Unit Input/Main Power Input Terminals, Connector for 24 VDC Power Supply Input/Regeneration Unit Thermal Input/Electromagnetic Brake Output Terminals, Connector connection lever
Safety Standards
  
Product Name Product Leadtime Unit Price(INR)
EAS6RY-E065-ARMCD-3Please contact us for more infoPlease contact us for more info

You cannot add this product to a cart. Sorry for your inconvenience but please contact to customer support centre.

●Production Information

Product to be discontinued (Order deadline, 31/Jan/2025)


●Component Name

EASM6RYE065ARMC(Actuator)
ARD-CD(Control Circuit)

Specifications

Motor TypeαSTEP AR Series
Linear Slide SizeWidth 75.4mm×Height 83mm
Table TypeY Table
Electromagnetic BrakeWith
Motor Connection DirectionRight side mounted
Driver TypeBuilt-In Controller Type
Drive SystemBall Screw
Repetitive Positioning Accuracy±0.02mm
ResolutionThe motor can be arbitrarily set resolution between 100~10000 [P / R].
Traveling Parallelism0.03mm
Stroke650mm
Lead6mm
Transportable Mass - Horizontal~60kg
Transportable Mass - Vertical~30kg
Thrust~360N
Pushing Force500N *1
Holding Force360N *2
Maximum Speed300mm/s
Electromagnetic Brake Power Supply Input Voltage24VDC ±5% *3
Electromagnetic Brake Power Supply Input Current0.25A or more
Power Supply Input - VoltageSingle-Phase 200-240VAC -15~+6%
Power Supply Input - Frequency50/60Hz
Power Supply Input - Current2.3A
Power Supply Input - Control Power Supply24VDC ±5% 0.5A
Mass: Actuator7.6kg
Mass: Control Circuit0.75kg
  • Dynamic Permissible Moment:Mp:31.8N・m、My:10.3N・m、Mr:40.6N・m
    Static Permissible Moment:Mp:86.0N・m、My:34.0N・m、Mr:110.0N・m
  • * The UL/CSA/CE mark on the actuator part is not the actuator product name. It is the motor product name.
  • *1 Use it with the pushing operation speed at 25 mm/s or less, and within the dynamic permissible moment.
    *2 Holding force when the motor is stopped or when the electromagnetic brake is operating, while power is supplied.
    *3 If the wiring distance between the motor and driver is extended to 20 m or longer using an accessory cable (sold separately), the 24 VDC±4% specification applies.

Download

The link of Web2CAD site can be used for 3D CAD data downloading as well. For more details, please click here.

2D-CAD Motorized Linear SlideD4050.dxf
Control CircuitB797.dxf
3D-CAD Motorized Linear Slide(STEP)D4050.zip
Control CircuitB797.step
Document APPENDIX UL Standards for AR SeriesHM-60116E.pdf
UL Certification(Motor)UL_E64199V6S1.pdf
UL Certification(Circuit)UL_E171462V4S13.pdf
CE Declaration of ConformityDoC-6084.pdf
Catalogue Motorized Linear Slides EAS Series Motorized Cylinders EAC SeriesEAS_EAC serie lo.pdf
Operating Manual Motorized Linear Slides EAS Series Actuator Edition OPERATING MANUALHL-17168E.pdf
Motorized actuator Function Setting EditionHL-17193E.pdf
AR Series/Motorized actuator equipped the AR Series AC power input/DC power input Built-in Controller TypeHM-60340E.pdf
Data Setter OPX-2A OPERATING MANUAL Before UseHM-40142E.pdf
Data Setter OPX-2A OPERATING MANUAL DGII Series / EAS Series Built-in Controller TypeHL-14055E.pdf