The specialist of small precision motors - ORIENTAL MOTOR (INDIA) > Q&A > Controllers Qn 6: I am currently using the EMP401-1 controller with my ARD-C driver, and I am experiencing an alarm error every time I try to run my sequence. What could be the issue?
Controllers:I am currently using the EMP401-1 controller with my ARD-C driver, and I am experiencing an alarm error every time I try to run my sequence. What could be the issue?
Question 6: I am currently using the EMP401-1 controller with my ARD-C driver, and I am experiencing an alarm error every time I try to run my sequence. What could be the issue?

Answer : This is due to the ACTL command, this command switches the logical value of a sensor or an alarm, and this is normally set to, ACTL1 0,0,0,1,1, whereby the driver alarm input logic and alarm output logic is normally close (1). To run your sequence, do change this command to ACTL1 0,0,0,0,0.