Electric Linear Slides EAS Series

EASM4YE040ARMC

EASM4YE040ARMC

Actuator

Connection Cable (Actuator~Control Circuit)

Product Classification Product Name List Price Shipping Date
Actuator EASM4YE040ARMC Rs. 61,200 30 Working Days (Dispatch)
• This product is an actuator only. A combination with the following products is required for driving.
• Driver: Select the driver that best describes your needs from the [Driver Introduction].
• The motor cable and electromagnetic brake cable from the motor cannot be connected directly to the driver. When connecting to the driver, use a connection cable.

Included

  • Actuator: None

Specifications

Dimensions

Connection Cable (When Selected)
Connection Cable (When Selected)

Connection Cable (When Selected)

Flexible Connection Cable (When Selected)
Flexible Connection Cable (When Selected)

Flexible Connection Cable (When Selected)

Data Download

Other Specifications

Calculating Load Moment

When a load is transported with an electric linear slide or electric cylinder (a unit equipped with shaft guide covers only), the load moment acts on the linear guide/shaft guide if the position of the load's center of gravity is offset from the center of the table/center of the shaft guide. The direction of action applies to the directions for pitching (MP), yawing (MY), and rolling (MR), depending on the position of the offset.

Load Moment of Electric Linear Slide Load Moment of Electric Cylinder (Units equipped with shaft guide only)

Even though the selected electric actuators satisfy the load mass and positioning time requirements, when the center of gravity of the load is overhung from the table's center/shaft guide’s center, the run life may decrease as a result of the load moment. Load moment calculations must be completed and whether the conditions are within specifications values must be checked. The moment applied under static conditions is the static permissible moment. The moment applied under movement is the dynamic permissible moment, and both must be checked.

Calculate the load moment of the electric linear slides and electric cylinders (units equipped with shaft guide covers only) based on loads that are applied. Check that the static permissible moment and dynamic permissible moment are within limits and check that strength is sufficient.

G: Position of the Load's Center of Gravity
  • *For more information on calculating static permissible moment and dynamic permissible moments, click here.

Load Moment Formula

\(\begin{align}\frac{|\Delta \mathrm{M_P}|}{\mathrm{M_P}}+\frac{|\Delta \mathrm{M_Y}|}{\mathrm{M_Y}}+ \frac{|\Delta \mathrm{M_R}|}{\mathrm{M_R}}\leqq 1 \end{align}\)

When there are several overhung loads, etc., it is determined by the sum of moments from all loads.

For Multiple Loads (n)

\(\begin{align}\frac{|\Delta \mathrm{M_{P1}} + \Delta \mathrm{M_{P2}} + \cdots \Delta \mathrm{M_{Pn}}|}{\mathrm{M_P}} + \frac{|\Delta \mathrm{M_{Y1}} + \Delta \mathrm{M_{Y2}} + \cdots \Delta \mathrm{M_{Yn}}|}{\mathrm{M_Y}} + \frac{|\Delta \mathrm{M_{R1}} + \Delta \mathrm{M_{R2}} + \cdots \Delta \mathrm{M_{Rn}}|}{\mathrm{M_R}} \leqq 1 \end{align}\)

Travel Direction

At the time of shipment, the travel direction of the table is set as follows.

Motor Mounting: Straight Type Motor Mounting: Reversed Motor Type

Standards

Regulations and Standards Materials

Documents about compliance with regulations and standards can be downloaded from the "Data Download" tab on the product details page.
(The types of files available for download vary by product.)

Explanations of the Global Laws, Regulations and Standards can be found here.

Information about our compliance with regulations and standards for each of our product series can be found here.

Hazardous Substances

The product does not contain any substances (10 substances) exceeding the regulation values of the RoHS Directive (2011/65/EU, 2015/863/EU).

Driver Introduction

You can choose from the following drivers. Click here for details on driver features and product lines

Driver Type Features Product Name

Built-in Controller Type

ARD-AD2
Features

With this type, operation data is set in the driver, then selected and executed from the host system.
Host system connection and control can be performed with any of the following: I/O, Modbus (RTU), RS-485 communication, or an industrial network.
Using the network converter (sold separately), CC-Link, MECHATROLINK, and EtherCAT communications are possible.
 

  • I would like to run it using an industrial network
  • I would like to run it using RS-485 communication
  • I would like to acquire motor information from a host controller or a touch screen
Product Name

Single-Phase 100-120 VAC
ARD-AD2

Single-Phase/Three-Phase 200-240 VAC
ARD-CD2

Driver Type

Pulse Input Type

ARD-A
Features

Operation is executed according to the pulse signal input to the driver.
The motor is controlled from a positioning module (pulse generator) provided by the customer.
Status information for the motor (position, speed, torque, alarms, temperature, and more) can be monitored by using the support software MEXE02.
 

  • I would like to run it using pulse input
  • I would like to obtain motor information via support software MEXE02
Product Name

Single-Phase 100-115 VAC
ARD-A

Single-Phase 200-230 VAC
ARD-C

Three-Phase 200-230 VAC
ARD-S

close
close
close
close